As described in the CIBSE CP1 Heat networks code of practice.
| A | Primary pipework (or primary heat network). |
| B | Secondary pipework (or secondary heat network). |
| C | Tertiary pipework (or tertiary heat network, heating and DHWS internal to the apartment and separated from the primary network). |
| D | Sub Station |
The Substation separates the buildings from the district heating pipe network or used as a pressure break in very high building to prevent extreme pressure differentials.
Where the temperatures and pressures of the building’s heating systems differ from those of the district heating network, it is usually necessary to utilise a Substation. A Substation consists of a plate heat exchanger which creates pressure break between the district network and consumer system.
The district heating supplier will provide information on the actual minimum and maximum differential pressures, as measured at the service connection valves. This data should be used for determining the sizes and capacities of control valves and heat exchangers.
As described in the CIBSE CP1 Heat networks code of practice.
| A | Primary pipework (or primary heat network). |
| B | Secondary pipework (or secondary heat network). |
| C | Tertiary pipework (or tertiary heat network, heating and DHWS internal to the apartment and separated from the primary network). |
| D | Sub Station |
The Substation separates the buildings from the district heating pipe network or used as a pressure break in very high building to prevent extreme pressure differentials.
Where the temperatures and pressures of the building’s heating systems differ from those of the district heating network, it is usually necessary to utilise a Substation. A Substation consists of a plate heat exchanger which creates pressure break between the district network and consumer system.
The district heating supplier will provide information on the actual minimum and maximum differential pressures, as measured at the service connection valves. This data should be used for determining the sizes and capacities of control valves and heat exchangers.
Should you require technical support for the Hiper HIU unit during this period, please contact one of our service providers in your area, who will be happy to help.
Please note, you will be required to provide the following information:
Cover: Scotland
Phone: 0141 4141411
Email: scotland@thermalcare.co.uk
Please call the office number and this will put you thought to out of hours.
Cover: London Areas
Phone: 0800 195 6468
Email: info@lhe.london
Address: Office 7, 35-37 Ludgate Hill, London RM10 8LH
Cover: England
Address: Building Centre, 26 Store Street, London, WC1E 7BT
Phone: 077 0449 7243
Email: aruna@heatweb.co.uk
Cover: Midlands, North & North Wales
Address: Unit 3 Chemical Lane Longbridge Hayes Ind Estate, Stoke-on-Trent , ST6 4BP
Phone: 01782 630656
Email: ange.holland@HMM.co.uk
Cover: London Areas
Phone: 07725920241
Email: aaron@hiumechservices.com
Address: 53A lansdowne lane , London, SE7 8TN